sushy.resources.chassis package¶
Subpackages¶
- sushy.resources.chassis.power package
- Submodules
- sushy.resources.chassis.power.constants module
LineInputVoltageType
LineInputVoltageType.AC_120V
LineInputVoltageType.AC_240V
LineInputVoltageType.AC_277V
LineInputVoltageType.AC_AND_DC_WIDE_RANGE
LineInputVoltageType.AC_HIGH_LINE
LineInputVoltageType.AC_LOW_LINE
LineInputVoltageType.AC_MID_LINE
LineInputVoltageType.AC_WIDE_RANGE
LineInputVoltageType.DC_240V
LineInputVoltageType.DC_380V
LineInputVoltageType.DC_NEG48V
LineInputVoltageType.UNKNOWN
PowerInputType
PowerSupplyType
- sushy.resources.chassis.power.power module
InputRangeListField
Power
PowerSupplyListField
PowerSupplyListField.firmware_version
PowerSupplyListField.identity
PowerSupplyListField.indicator_led
PowerSupplyListField.input_ranges
PowerSupplyListField.last_power_output_watts
PowerSupplyListField.line_input_voltage
PowerSupplyListField.line_input_voltage_type
PowerSupplyListField.manufacturer
PowerSupplyListField.model
PowerSupplyListField.name
PowerSupplyListField.part_number
PowerSupplyListField.power_capacity_watts
PowerSupplyListField.power_supply_type
PowerSupplyListField.serial_number
PowerSupplyListField.spare_part_number
PowerSupplyListField.status
- Module contents
- sushy.resources.chassis.thermal package
Submodules¶
sushy.resources.chassis.chassis module¶
- class sushy.resources.chassis.chassis.ActionsField(*args, **kwargs)¶
Bases:
CompositeField
- reset = <sushy.resources.common.ResetActionField object>¶
- class sushy.resources.chassis.chassis.Chassis(connector, identity, redfish_version=None, registries=None, root=None)¶
Bases:
ResourceBase
Chassis resource
The Chassis represents the physical components of a system. This resource represents the sheet-metal confined spaces and logical zones such as racks, enclosures, chassis and all other containers.
- asset_tag = <sushy.resources.base.Field object>¶
The user assigned asset tag of this chassis
- chassis_type = <sushy.resources.base.MappedField object>¶
The type of physical form factor of the chassis
- depth_mm = <sushy.resources.base.Field object>¶
Depth in millimeters The depth of the chassis. The value of this property shall represent the depth (length) of the chassis (in millimeters) as specified by the manufacturer.
- description = <sushy.resources.base.Field object>¶
The chassis description
- get_allowed_reset_chassis_values()¶
Get the allowed values for resetting the chassis.
- Returns:
A set of allowed values.
- Raises:
MissingAttributeError, if Actions/#Chassis.Reset attribute not present.
- height_mm = <sushy.resources.base.Field object>¶
Height in millimeters The height of the chassis. The value of this property shall represent the height of the chassis (in millimeters) as specified by the manufacturer.
- identity = <sushy.resources.base.Field object>¶
Identifier for the chassis
- indicator_led = <sushy.resources.base.MappedField object>¶
The state of the indicator LED, used to identify the chassis
- property managers¶
A list of managers for this chassis.
Returns a list of Manager objects representing the managers that manage this chassis.
- Raises:
MissingAttributeError if ‘@odata.id’ field is missing.
- Returns:
A list of Manager instances
- manufacturer = <sushy.resources.base.Field object>¶
The manufacturer of this chassis
- model = <sushy.resources.base.Field object>¶
The model number of the chassis
- name = <sushy.resources.base.Field object>¶
The chassis name
- property network_adapters¶
Property to reference NetworkAdapterCollection instance
It is set once when the first time it is queried. On refresh, this property is marked as stale (greedy-refresh not done). Here the actual refresh of the sub-resource happens, if stale.
- part_number = <sushy.resources.base.Field object>¶
The part number of the chassis
- physical_security = <sushy.resources.chassis.chassis.PhysicalSecurity object>¶
PhysicalSecurity This value of this property shall contain the sensor state of the physical security.
- property power¶
Property to reference Power instance
It is set once when the first time it is queried. On refresh, this property is marked as stale (greedy-refresh not done). Here the actual refresh of the sub-resource happens, if stale.
- power_state = <sushy.resources.base.MappedField object>¶
The current power state of the chassis
- reset_chassis(value)¶
Reset the chassis.
- Parameters:
value – The target value.
- Raises:
InvalidParameterValueError, if the target value is not allowed.
- serial_number = <sushy.resources.base.Field object>¶
The serial number of the chassis
- set_indicator_led(state)¶
Set IndicatorLED to the given state.
- Parameters:
state – Desired LED state, an IndicatorLED value.
- Raises:
InvalidParameterValueError, if any information passed is invalid.
- sku = <sushy.resources.base.Field object>¶
Stock-keeping unit number (SKU) The value of this property shall be the stock-keeping unit number for this chassis.
- status = <sushy.resources.common.StatusField object>¶
Status and Health This property describes the status and health of the chassis and its children.
- property systems¶
A list of systems residing in this chassis.
Returns a list of System objects representing systems being mounted in this chassis/cabinet.
- Raises:
MissingAttributeError if ‘@odata.id’ field is missing.
- Returns:
A list of System instances
- property thermal¶
Property to reference Thermal instance
It is set once when the first time it is queried. On refresh, this property is marked as stale (greedy-refresh not done). Here the actual refresh of the sub-resource happens, if stale.
- uuid = <sushy.resources.base.Field object>¶
The Universal Unique Identifier (UUID) for this Chassis.
- weight_kg = <sushy.resources.base.Field object>¶
Weight in kilograms The value of this property shall represent the published mass (commonly referred to as weight) of the chassis (in kilograms).
- width_mm = <sushy.resources.base.Field object>¶
Width in millimeters The value of this property shall represent the width of the chassis (in millimeters) as specified by the manufacturer.
- class sushy.resources.chassis.chassis.ChassisCollection(connector, path, redfish_version=None, registries=None, root=None)¶
Bases:
ResourceCollectionBase
- class sushy.resources.chassis.chassis.PhysicalSecurity(*args, **kwargs)¶
Bases:
CompositeField
- intrusion_sensor = <sushy.resources.base.MappedField object>¶
IntrusionSensor This indicates the known state of the physical security sensor, such as if it is hardware intrusion detected.
- intrusion_sensor_number = <sushy.resources.base.Field object>¶
A numerical identifier to represent the physical security sensor
- intrusion_sensor_re_arm = <sushy.resources.base.MappedField object>¶
This indicates how the Normal state to be restored
sushy.resources.chassis.constants module¶
- class sushy.resources.chassis.constants.ChassisType(value)¶
Bases:
Enum
Chassis Types constants
- BLADE = 'Blade'¶
An enclosed or semi-enclosed, typically vertically-oriented, system chassis that must be plugged into a multi-system chassis to function normally.
- CARD = 'Card'¶
A loose device or circuit board intended to be installed in a system or other enclosure.
- CARTRIDGE = 'Cartridge'¶
A small self-contained system intended to be plugged into a multi- system chassis.
- COMPONENT = 'Component'¶
A small chassis, card, or device that contains devices for a particular subsystem or function.
- DRAWER = 'Drawer'¶
An enclosed or semi-enclosed, typically horizontally-oriented, system chassis that can be slid into a multi-system chassis.
- ENCLOSURE = 'Enclosure'¶
A generic term for a chassis that does not fit any other description.
- EXPANSION = 'Expansion'¶
A chassis that expands the capabilities or capacity of another chassis.
- IP_BASED_DRIVE = 'IPBasedDrive'¶
A chassis in a drive form factor with IP-based network connections.
- MODULE = 'Module'¶
A small, typically removable, chassis or card that contains devices for a particular subsystem or function.
- OTHER = 'Other'¶
A chassis that does not fit any of these definitions.
- POD = 'Pod'¶
A collection of equipment racks in a large, likely transportable, container.
- RACK = 'Rack'¶
An equipment rack, typically a 19-inch wide freestanding unit.
- RACK_GROUP = 'RackGroup'¶
A group of racks that form a single entity or share infrastructure.
- RACK_MOUNT = 'RackMount'¶
A single-system chassis designed specifically for mounting in an equipment rack.
- ROW = 'Row'¶
A collection of equipment racks.
- SHELF = 'Shelf'¶
An enclosed or semi-enclosed, typically horizontally-oriented, system chassis that must be plugged into a multi-system chassis to function normally.
- SIDECAR = 'Sidecar'¶
A chassis that mates mechanically with another chassis to expand its capabilities or capacity.
- SLED = 'Sled'¶
An enclosed or semi-enclosed, system chassis that must be plugged into a multi-system chassis to function normally similar to a blade type chassis.
- STAND_ALONE = 'StandAlone'¶
A single, free-standing system, commonly called a tower or desktop chassis.
- STORAGE_ENCLOSURE = 'StorageEnclosure'¶
A chassis that encloses storage.
- ZONE = 'Zone'¶
A logical division or portion of a physical chassis that contains multiple devices or systems that cannot be physically separated.
- class sushy.resources.chassis.constants.IntrusionSensor(value)¶
Bases:
Enum
Chassis IntrusionSensor constants
- HARDWARE_INTRUSION = 'HardwareIntrusion'¶
A door, lock, or other mechanism protecting the internal system hardware from being accessed is detected to be in an insecure state.
- NORMAL = 'Normal'¶
No abnormal physical security condition is detected at this time.
- TAMPERING_DETECTED = 'TamperingDetected'¶
Physical tampering of the monitored entity is detected.
- class sushy.resources.chassis.constants.IntrusionSensorReArm(value)¶
Bases:
Enum
Chassis IntrusionSensorReArm constants
- AUTOMATIC = 'Automatic'¶
Because no abnormal physical security condition is detected, this sensor is automatically restored to the normal state.
- MANUAL = 'Manual'¶
A manual re-arm of this sensor restores it to the normal state.