bgp_dragent.ini

DEFAULT

debug
Type:

boolean

Default:

False

Mutable:

This option can be changed without restarting.

If set to true, the logging level will be set to DEBUG instead of the default INFO level.

log_config_append
Type:

string

Default:

<None>

Mutable:

This option can be changed without restarting.

The name of a logging configuration file. This file is appended to any existing logging configuration files. For details about logging configuration files, see the Python logging module documentation. Note that when logging configuration files are used then all logging configuration is set in the configuration file and other logging configuration options are ignored (for example, log-date-format).

Deprecated Variations

Group

Name

DEFAULT

log-config

DEFAULT

log_config

log_date_format
Type:

string

Default:

%Y-%m-%d %H:%M:%S

Defines the format string for %(asctime)s in log records. Default: the value above . This option is ignored if log_config_append is set.

log_file
Type:

string

Default:

<None>

(Optional) Name of log file to send logging output to. If no default is set, logging will go to stderr as defined by use_stderr. This option is ignored if log_config_append is set.

Deprecated Variations

Group

Name

DEFAULT

logfile

log_dir
Type:

string

Default:

<None>

(Optional) The base directory used for relative log_file paths. This option is ignored if log_config_append is set.

Deprecated Variations

Group

Name

DEFAULT

logdir

watch_log_file
Type:

boolean

Default:

False

Uses logging handler designed to watch file system. When log file is moved or removed this handler will open a new log file with specified path instantaneously. It makes sense only if log_file option is specified and Linux platform is used. This option is ignored if log_config_append is set.

Warning

This option is deprecated for removal. Its value may be silently ignored in the future.

Reason:

This function is known to have bene broken for long time, and depends on the unmaintained library

use_syslog
Type:

boolean

Default:

False

Use syslog for logging. Existing syslog format is DEPRECATED and will be changed later to honor RFC5424. This option is ignored if log_config_append is set.

use_journal
Type:

boolean

Default:

False

Enable journald for logging. If running in a systemd environment you may wish to enable journal support. Doing so will use the journal native protocol which includes structured metadata in addition to log messages.This option is ignored if log_config_append is set.

syslog_log_facility
Type:

string

Default:

LOG_USER

Syslog facility to receive log lines. This option is ignored if log_config_append is set.

use_json
Type:

boolean

Default:

False

Use JSON formatting for logging. This option is ignored if log_config_append is set.

use_stderr
Type:

boolean

Default:

False

Log output to standard error. This option is ignored if log_config_append is set.

use_eventlog
Type:

boolean

Default:

False

Log output to Windows Event Log.

Warning

This option is deprecated for removal. Its value may be silently ignored in the future.

Reason:

Windows support is no longer maintained.

log_color
Type:

boolean

Default:

False

(Optional) Set the ‘color’ key according to log levels. This option takes effect only when logging to stderr or stdout is used. This option is ignored if log_config_append is set.

log_rotate_interval
Type:

integer

Default:

1

The amount of time before the log files are rotated. This option is ignored unless log_rotation_type is set to “interval”.

log_rotate_interval_type
Type:

string

Default:

days

Valid Values:

Seconds, Minutes, Hours, Days, Weekday, Midnight

Rotation interval type. The time of the last file change (or the time when the service was started) is used when scheduling the next rotation.

max_logfile_count
Type:

integer

Default:

30

Maximum number of rotated log files.

max_logfile_size_mb
Type:

integer

Default:

200

Log file maximum size in MB. This option is ignored if “log_rotation_type” is not set to “size”.

log_rotation_type
Type:

string

Default:

none

Valid Values:

interval, size, none

Log rotation type.

Possible values

interval

Rotate logs at predefined time intervals.

size

Rotate logs once they reach a predefined size.

none

Do not rotate log files.

logging_context_format_string
Type:

string

Default:

%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [%(global_request_id)s %(request_id)s %(user_identity)s] %(instance)s%(message)s

Format string to use for log messages with context. Used by oslo_log.formatters.ContextFormatter

logging_default_format_string
Type:

string

Default:

%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [-] %(instance)s%(message)s

Format string to use for log messages when context is undefined. Used by oslo_log.formatters.ContextFormatter

logging_debug_format_suffix
Type:

string

Default:

%(funcName)s %(pathname)s:%(lineno)d

Additional data to append to log message when logging level for the message is DEBUG. Used by oslo_log.formatters.ContextFormatter

logging_exception_prefix
Type:

string

Default:

%(asctime)s.%(msecs)03d %(process)d ERROR %(name)s %(instance)s

Prefix each line of exception output with this format. Used by oslo_log.formatters.ContextFormatter

logging_user_identity_format
Type:

string

Default:

%(user)s %(project)s %(domain)s %(system_scope)s %(user_domain)s %(project_domain)s

Defines the format string for %(user_identity)s that is used in logging_context_format_string. Used by oslo_log.formatters.ContextFormatter

default_log_levels
Type:

list

Default:

['amqp=WARN', 'amqplib=WARN', 'boto=WARN', 'qpid=WARN', 'sqlalchemy=WARN', 'suds=INFO', 'oslo.messaging=INFO', 'oslo_messaging=INFO', 'iso8601=WARN', 'requests.packages.urllib3.connectionpool=WARN', 'urllib3.connectionpool=WARN', 'websocket=WARN', 'requests.packages.urllib3.util.retry=WARN', 'urllib3.util.retry=WARN', 'keystonemiddleware=WARN', 'routes.middleware=WARN', 'stevedore=WARN', 'taskflow=WARN', 'keystoneauth=WARN', 'oslo.cache=INFO', 'oslo_policy=INFO', 'dogpile.core.dogpile=INFO']

List of package logging levels in logger=LEVEL pairs. This option is ignored if log_config_append is set.

publish_errors
Type:

boolean

Default:

False

Enables or disables publication of error events.

instance_format
Type:

string

Default:

"[instance: %(uuid)s] "

The format for an instance that is passed with the log message.

instance_uuid_format
Type:

string

Default:

"[instance: %(uuid)s] "

The format for an instance UUID that is passed with the log message.

rate_limit_interval
Type:

integer

Default:

0

Interval, number of seconds, of log rate limiting.

rate_limit_burst
Type:

integer

Default:

0

Maximum number of logged messages per rate_limit_interval.

rate_limit_except_level
Type:

string

Default:

CRITICAL

Valid Values:

CRITICAL, ERROR, INFO, WARNING, DEBUG, ‘’

Log level name used by rate limiting. Logs with level greater or equal to rate_limit_except_level are not filtered. An empty string means that all levels are filtered.

fatal_deprecations
Type:

boolean

Default:

False

Enables or disables fatal status of deprecations.

bgp

bgp_speaker_driver
Type:

string

Default:

<None>

BGP speaker driver class to be instantiated.

bgp_router_id
Type:

string

Default:

<None>

32-bit BGP identifier, typically an IPv4 address owned by the system running the BGP DrAgent.