bgp_dragent.ini¶
DEFAULT¶
- debug¶
- Type:
boolean
- Default:
False
- Mutable:
This option can be changed without restarting.
If set to true, the logging level will be set to DEBUG instead of the default INFO level.
- log_config_append¶
- Type:
string
- Default:
<None>
- Mutable:
This option can be changed without restarting.
The name of a logging configuration file. This file is appended to any existing logging configuration files. For details about logging configuration files, see the Python logging module documentation. Note that when logging configuration files are used then all logging configuration is set in the configuration file and other logging configuration options are ignored (for example, log-date-format).
¶ Group
Name
DEFAULT
log-config
DEFAULT
log_config
- log_date_format¶
- Type:
string
- Default:
%Y-%m-%d %H:%M:%S
Defines the format string for %(asctime)s in log records. Default: the value above . This option is ignored if log_config_append is set.
- log_file¶
- Type:
string
- Default:
<None>
(Optional) Name of log file to send logging output to. If no default is set, logging will go to stderr as defined by use_stderr. This option is ignored if log_config_append is set.
¶ Group
Name
DEFAULT
logfile
- log_dir¶
- Type:
string
- Default:
<None>
(Optional) The base directory used for relative log_file paths. This option is ignored if log_config_append is set.
¶ Group
Name
DEFAULT
logdir
- watch_log_file¶
- Type:
boolean
- Default:
False
Uses logging handler designed to watch file system. When log file is moved or removed this handler will open a new log file with specified path instantaneously. It makes sense only if log_file option is specified and Linux platform is used. This option is ignored if log_config_append is set.
Warning
This option is deprecated for removal. Its value may be silently ignored in the future.
- Reason:
This function is known to have bene broken for long time, and depends on the unmaintained library
- use_syslog¶
- Type:
boolean
- Default:
False
Use syslog for logging. Existing syslog format is DEPRECATED and will be changed later to honor RFC5424. This option is ignored if log_config_append is set.
- use_journal¶
- Type:
boolean
- Default:
False
Enable journald for logging. If running in a systemd environment you may wish to enable journal support. Doing so will use the journal native protocol which includes structured metadata in addition to log messages.This option is ignored if log_config_append is set.
- syslog_log_facility¶
- Type:
string
- Default:
LOG_USER
Syslog facility to receive log lines. This option is ignored if log_config_append is set.
- use_json¶
- Type:
boolean
- Default:
False
Use JSON formatting for logging. This option is ignored if log_config_append is set.
- use_stderr¶
- Type:
boolean
- Default:
False
Log output to standard error. This option is ignored if log_config_append is set.
- use_eventlog¶
- Type:
boolean
- Default:
False
Log output to Windows Event Log.
Warning
This option is deprecated for removal. Its value may be silently ignored in the future.
- Reason:
Windows support is no longer maintained.
- log_color¶
- Type:
boolean
- Default:
False
(Optional) Set the ‘color’ key according to log levels. This option takes effect only when logging to stderr or stdout is used. This option is ignored if log_config_append is set.
- log_rotate_interval¶
- Type:
integer
- Default:
1
The amount of time before the log files are rotated. This option is ignored unless log_rotation_type is set to “interval”.
- log_rotate_interval_type¶
- Type:
string
- Default:
days
- Valid Values:
Seconds, Minutes, Hours, Days, Weekday, Midnight
Rotation interval type. The time of the last file change (or the time when the service was started) is used when scheduling the next rotation.
- max_logfile_count¶
- Type:
integer
- Default:
30
Maximum number of rotated log files.
- max_logfile_size_mb¶
- Type:
integer
- Default:
200
Log file maximum size in MB. This option is ignored if “log_rotation_type” is not set to “size”.
- log_rotation_type¶
- Type:
string
- Default:
none
- Valid Values:
interval, size, none
Log rotation type.
Possible values
- interval
Rotate logs at predefined time intervals.
- size
Rotate logs once they reach a predefined size.
- none
Do not rotate log files.
- logging_context_format_string¶
- Type:
string
- Default:
%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [%(global_request_id)s %(request_id)s %(user_identity)s] %(instance)s%(message)s
Format string to use for log messages with context. Used by oslo_log.formatters.ContextFormatter
- logging_default_format_string¶
- Type:
string
- Default:
%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [-] %(instance)s%(message)s
Format string to use for log messages when context is undefined. Used by oslo_log.formatters.ContextFormatter
- logging_debug_format_suffix¶
- Type:
string
- Default:
%(funcName)s %(pathname)s:%(lineno)d
Additional data to append to log message when logging level for the message is DEBUG. Used by oslo_log.formatters.ContextFormatter
- logging_exception_prefix¶
- Type:
string
- Default:
%(asctime)s.%(msecs)03d %(process)d ERROR %(name)s %(instance)s
Prefix each line of exception output with this format. Used by oslo_log.formatters.ContextFormatter
- logging_user_identity_format¶
- Type:
string
- Default:
%(user)s %(project)s %(domain)s %(system_scope)s %(user_domain)s %(project_domain)s
Defines the format string for %(user_identity)s that is used in logging_context_format_string. Used by oslo_log.formatters.ContextFormatter
- default_log_levels¶
- Type:
list
- Default:
['amqp=WARN', 'amqplib=WARN', 'boto=WARN', 'qpid=WARN', 'sqlalchemy=WARN', 'suds=INFO', 'oslo.messaging=INFO', 'oslo_messaging=INFO', 'iso8601=WARN', 'requests.packages.urllib3.connectionpool=WARN', 'urllib3.connectionpool=WARN', 'websocket=WARN', 'requests.packages.urllib3.util.retry=WARN', 'urllib3.util.retry=WARN', 'keystonemiddleware=WARN', 'routes.middleware=WARN', 'stevedore=WARN', 'taskflow=WARN', 'keystoneauth=WARN', 'oslo.cache=INFO', 'oslo_policy=INFO', 'dogpile.core.dogpile=INFO']
List of package logging levels in logger=LEVEL pairs. This option is ignored if log_config_append is set.
- publish_errors¶
- Type:
boolean
- Default:
False
Enables or disables publication of error events.
- instance_format¶
- Type:
string
- Default:
"[instance: %(uuid)s] "
The format for an instance that is passed with the log message.
- instance_uuid_format¶
- Type:
string
- Default:
"[instance: %(uuid)s] "
The format for an instance UUID that is passed with the log message.
- rate_limit_interval¶
- Type:
integer
- Default:
0
Interval, number of seconds, of log rate limiting.
- rate_limit_burst¶
- Type:
integer
- Default:
0
Maximum number of logged messages per rate_limit_interval.
- rate_limit_except_level¶
- Type:
string
- Default:
CRITICAL
- Valid Values:
CRITICAL, ERROR, INFO, WARNING, DEBUG, ‘’
Log level name used by rate limiting. Logs with level greater or equal to rate_limit_except_level are not filtered. An empty string means that all levels are filtered.
- fatal_deprecations¶
- Type:
boolean
- Default:
False
Enables or disables fatal status of deprecations.
bgp¶
- bgp_speaker_driver¶
- Type:
string
- Default:
<None>
BGP speaker driver class to be instantiated.
- bgp_router_id¶
- Type:
string
- Default:
<None>
32-bit BGP identifier, typically an IPv4 address owned by the system running the BGP DrAgent.