Built-in hardware managers¶
GenericHardwareManager¶
This is the default hardware manager for ironic-python-agent. It provides support for Hardware Inventory and the default deploy and clean steps.
Deploy steps¶
deploy.write_image(node, ports, image_info, configdrive=None)
A deploy step backing the
write_image
deploy step of the direct deploy interface. Should not be used explicitly, but can be overridden to provide a custom way of writing an image.deploy.erase_devices_metadata(node, ports)
Erases partition tables from all recognized disk devices. Can be used with software RAID since it requires empty holder disks.
raid.apply_configuration(node, ports, raid_config, delete_existing=True)
Apply a software RAID configuration. It belongs to the
raid
interface and must be used through the ironic RAID feature.
Injecting files¶
deploy.inject_files(node, ports, files, verify_ca=True)
This optional deploy step (introduced in the Wallaby release series) allows
injecting arbitrary files into the node. The list of files is built from the
optional inject_files
property of the node concatenated with the explicit
files
argument. Each item in the list is a dictionary with the following
fields:
path
(required)An absolute path to the file on the target partition. All missing directories will be created.
partition
Specifies the target partition in one of 3 ways:
A number is treated as a partition index (starting with 1) on the root device.
A path is treated as a block device path (e.g.
/dev/sda1
or/dev/disk/by-partlabel/<something>
.If missing, the agent will try to find a partition containing the first component of the
path
on the root device. E.g. for/etc/sysctl.d/my.conf
, look for a partition containing/etc
.
deleted
If
True
, the file is deleted, not created. Incompatible withcontent
.content
Data to write. Incompatible with
deleted
. Can take two forms:A URL of the content. Can use Python-style formatting to build a node specific URL, e.g.
http://server/{node[uuid]}/{ports[0][address]}
.Base64 encoded binary contents.
mode
,owner
,group
Numeric mode, owner ID and group ID of the file.
dirmode
Numeric mode of the leaf directory if it has to be created.
This deploy step is disabled by default and can be enabled via a deploy
template or via the ipa-inject-files-priority
kernel parameter.
Known limitations:
Names are not supported for
owner
andgroup
.LVM is not supported.
Clean steps¶
deploy.burnin_cpu
Stress-test the CPUs of a node via stress-ng for a configurable amount of time. Disabled by default.
deploy.burnin_disk
Stress-test the disks of a node via fio. Disabled by default.
deploy.burnin_memory
Stress-test the memory of a node via stress-ng for a configurable amount of time. Disabled by default.
deploy.burnin_network
Stress-test the network of a pair of nodes via fio for a configurable amount of time. Disabled by default.
deploy.erase_devices
Securely erases all information from all recognized disk devices. Relatively fast when secure ATA erase is available, otherwise can take hours, especially on a virtual environment. Enabled by default.
deploy.erase_devices_metadata
Erases partition tables from all recognized disk devices. Can be used as an alternative to the much longer
erase_devices
step.deploy.erase_pstore
Erases entries from pstore, the kernel’s oops/panic logger. Disabled by default. Can be enabled via priority overrides.
raid.create_configuration
Create a RAID configuration. This step belongs to the
raid
interface and must be used through the ironic RAID feature.raid.delete_configuration
Delete the RAID configuration. This step belongs to the
raid
interface and must be used through the ironic RAID feature.
Cleaning safeguards¶
The stock hardware manager contains a number of safeguards to prevent unsafe conditions from occuring.
Devices Skip List¶
A list of devices that Ironic does not touch during the cleaning and deployment
process can be specified in the node properties field under
skip_block_devices
. This should be a list of dictionaries
containing hints to identify the drives. For example:
'skip_block_devices': [{'name': '/dev/vda', 'vendor': '0x1af4'}]
To prevent software RAID devices from being deleted, put their volume name
(defined in the target_raid_config
) to the list.
Note: one dictionary with one value for each of the logical disks. For example:
'skip_block_devices': [{'volume_name': 'large'}, {'volume_name': 'temp'}]